+ | === styroInkubator v2.0 === | ||
+ | Abmessungen Innen | ||
+ | |||
+ | B,T,H: 42x42x45cm | ||
+ | |||
+ | Außen | ||
+ | |||
+ | B,T,H: 50x49x49cm | ||
+ | |||
+ | Hülle aus Styrodur uWert= 0.04 | ||
+ | |||
+ | Dicken: Boden, | ||
+ | |||
+ | Oberfläche Innen | ||
+ | |||
+ | 4x(0.42x0.45) + 2x(0.42x0.42) = 1.1088qm | ||
+ | |||
+ | Oberfläche Außen | ||
+ | |||
+ | 6x(0.50x0.50) = 1.5qm | ||
+ | |||
+ | wärmedurchlass errechnet: Lamda/ | ||
+ | |||
+ | Scheibe 8mm=0.008m 0.28m*0.28m=0.0784qm LamdaGlas uWert = 0.76W/mk | ||
+ | |||
+ | 0.76/ | ||
+ | |||
+ | |||
+ | Energiebedarf gemessen bei 17k differenz = 23Watt (??? komisch ist: es ist weniger als für Hülle ohne Scheibe gerechnet, mit scheibe fehlen runde 126Watt ???? wo ist der fehler ?) |