 +=== styroInkubator v2.0 ===
  
 +Abmessungen Innen
 +
 +B,T,H: 42x42x45cm
 +
 +Außen
 +
 +B,T,H: 50x49x49cm
 +
 +Hülle aus Styrodur uWert= 0.04
 +
 +Dicken: Boden,Front: 50mm, Rest:40mm Styrodur
 +
 +Oberfläche Innen
 +
 +4x(0.42x0.45) + 2x(0.42x0.42) = 1.1088qm
 +
 +Oberfläche Außen
 +
 +6x(0.50x0.50) = 1.5qm
 +
 +wärmedurchlass errechnet: Lamda/Dicke[m] 0.004/0.004 = 1W/mk *1.5qm = 1.5W/1.5qm*k *17k = 25.5Watt/1.5qm/17k (ohne Scheibe)
 +
 +Scheibe 8mm=0.008m 0.28m*0.28m=0.0784qm LamdaGlas uWert = 0.76W/mk
 +
 +0.76/0.008m*0.0784qm= 7.5W/k * 17k = 126W/0.0784qm/17k
 + 
 +
 +Energiebedarf gemessen bei 17k differenz = 23Watt (??? komisch ist: es ist weniger als für Hülle ohne Scheibe gerechnet, mit scheibe fehlen runde 126Watt ???? wo ist der fehler ?)